Fire Rated Steel Doors

Internal Steel Collection — specialist specification

Fire Rated Steel Doors

Certified FD30 and FD60 doorsets built to the same slim steel-look proportions as the rest of the collection. Beautiful design and tested fire performance, specified together.

The short version

A steel door that happens to be certified

A fire-rated internal steel door is a tested doorset: leaf, frame, glass, seals, hinges and hardware assessed together and certified to hold back flame and smoke for a defined period. It is specified where a building needs to keep an escape route usable for long enough to leave safely.

The difference from a standard steel door is largely invisible. Inside the frame sit intumescent and smoke seals; the glass is a certified fire-rated make-up rather than ordinary toughened glass; the hinges and closer are part of the tested set. Externally the profile, the finish and the glazing bar layout are the same as the unrated doors elsewhere in the collection.

That matters because rated openings rarely sit alone. A hallway will often have a rated door to the garage and an unrated pair to the living room. Specified from the same collection, the two read as a matched set rather than a compromise.

Fire ratings explained

FD30, FD60 and what the letters mean

FD30

30 minutes

Thirty minutes of tested resistance to fire and hot gases.

The most commonly specified rating in domestic work. An FD30 doorset has been tested to hold back flame and smoke for at least thirty minutes, buying the time a household needs to leave by a protected route.

  • Integral garage to house
  • Utility and boot rooms
  • Rooms opening onto a protected stairway
  • Loft conversions in two and three storey homes

FD60

60 minutes

Sixty minutes, usually where the building is larger or shared.

FD60 doubles the tested period. It is generally driven by storey height, compartmentation strategy or shared occupancy rather than by preference, and is more common in apartments, hotels and commercial interiors than in individual houses.

  • Apartment entrances
  • Plant and boiler rooms
  • Compartment walls in larger buildings
  • Hotels, offices and schools

Integrity (E)

The ability of the doorset to stay in place and resist the passage of flame and hot gases. This is the property the FD number refers to.

Insulation (I)

Resistance to heat transfer through the doorset. Glazed steel doors are generally rated for integrity, with insulation achieved only in specific tested build-ups — which is why the glass specification matters.

Smoke control (Sa)

Cold smoke leakage is controlled by a separate seal. A door described as FD30S or FD60S carries smoke seals in addition to intumescent protection.

Certification

Performance comes from a tested doorset — leaf, frame, glass, seals, hinges and hardware assessed together. Substituting a component outside the tested scope invalidates the certification.

Testing

Systems are tested to BS 476-22 or BS EN 1634-1, and evidence is issued as a test report, an assessment or third-party certification. We supply the documentation with the quotation.

Do I need a fire rated door?

Where fire rated doors are commonly required

A rating is driven by the position of the opening and the fire strategy of the building, not by the material of the door. These are the situations we are most often asked about.

Integral garages

The door between a garage and the house is one of the most consistently required fire doors in domestic building work.

Utility and plant rooms

Rooms containing boilers, batteries, inverters or heat pumps are often separated from living space.

Protected stairways

Where a stair forms the escape route, rooms opening onto it are typically separated by rated doorsets.

Loft conversions

Adding a storey usually triggers a protected route, and with it a set of rated doors on the landing.

Apartment entrances

Entrance doors to flats are a compartment line and carry their own, usually higher, requirement.

Multi-storey homes

Three storeys and above changes the escape strategy, and the door schedule with it.

Commercial interiors

Offices, hotels, schools and hospitality spaces where compartmentation is set by the fire strategy.

This page is guidance, not a fire strategy. Final requirements should always be confirmed by your architect, designer or Building Control officer. Once the door schedule is settled, we build to it and supply the certification with the doors.

Available configurations

What can be certified, and what cannot

Certification is granted to a tested assembly, so the range of rated configurations is narrower than the unrated collection. We would rather set that out plainly than discover it at order stage.

Single doors

The core configuration, in the same slim profile and bar layouts as the unrated collection.

Available

Double doors

Rebated pairs with the correct closing sequence, co-ordinated so the doors read as a matched pair.

Available

Glazed screens

Fixed rated screens alongside or opposite a doorset, keeping the elevation continuous.

Available

Side panels

Full-height panels flanking the door, within tested pane size limits.

Available with conditions

Pane sizes are governed by the certified glass, so very wide panels may be split by a bar.

Over panels

Rated panels above the door head, useful where ceilings are high.

Available with conditions

Head detail and the wall build-up above must suit the tested frame fixing.

Internal partitions

Longer runs of rated glazed partition dividing rooms or corridors.

Available with conditions

Long runs are engineered as a partition system rather than a doorset, and are priced per project.

Sliding, pivot and bifold

Design-led moving configurations from the wider collection.

Not currently certified

Fire certification is achieved with hinged doorsets. Where a rated opening is required, we keep the sliding or pivot doors elsewhere in the plan so the aesthetic remains consistent.

Design options

Certified performance, without giving up the detail

Save anything that appeals — it travels with you into your Inspiration Collection and on into your consultation.

Finishes

  • BlackThe signature steel-look finish, matt or fine texture.
  • WhiteSofter in period interiors and pale hallways.
  • BronzeWarmer metallic tone that suits timber and stone.
  • Anthracite GreyRAL 7016, slightly quieter than a true black.
  • Bespoke RALAny RAL to order, including dual colour front and back.

Steel bar layouts

  • Single paneNo bars — the most contemporary option, subject to certified pane size.
  • Two-over-twoA single horizontal bar with one vertical, calm and balanced.
  • Three-over-threeThe classic steel proportion, familiar from the unrated collection.
  • Full gridA denser industrial grid for larger leaves and wider screens.

Approved fire rated glass

  • Clear fire-rated glassCertified clear glazing that reads as ordinary toughened glass.
  • Reeded fire-rated glassVertical fluting for privacy without losing light. Availability depends on the tested build-up.
  • Obscure fire-rated glassFully obscured for utility rooms, plant rooms and bathrooms.
  • Satin fire-rated glassAn even frosted surface, soft and contemporary.
  • Acoustic fire-rated laminateAdds sound reduction where the room needs to be quiet as well as protected.

Handles & hardware

  • Slim lever on roseMatt black, bronze or satin stainless, matched to the rest of the collection.
  • Pull handle with latchWhere a longer vertical pull suits the proportion of the leaf.
  • Concealed door closerFitted within the head so the self-closing requirement is met discreetly.
  • Certified hingesFire-tested hinges supplied as part of the certified doorset.
  • Intumescent and smoke sealsHoused in the frame rebate and barely visible when the door is closed.

Technical

Specification and compliance

Figures depend on the certified doorset selected. Full test evidence, glass data and frame details are issued with every quotation and are available earlier for specification packs.

FD30 / FD60 certification summary

Test evidence and scope of certification for the specified doorset.

Frame and wall build-up details

Head, jamb and threshold sections with fixing centres.

Fire-rated glass data sheets

Certified glass build-ups, pane size limits and acoustic figures.

Hardware schedule template

Hinges, closers, latches and seals as a tested set.

Request The Technical Pack
Fire certification
FD30 and FD60 tested doorsets, to BS 476-22 or BS EN 1634-1
Smoke control
Sa cold smoke seals available on both ratings
Glass
Certified fire-rated glazing only; clear, reeded, obscure, satin or acoustic laminate
Seals
Intumescent strip within the frame rebate, smoke brush or fin where specified
Frame construction
Slim steel-look frame, fixed to a tested wall build-up
Maximum sizes
Typically to 2,400mm leaf height; larger openings resolved with over panels or screens
Acoustic performance
Up to around 38dB Rw with laminated acoustic glazing
Door closers
Self-closing device required on rated doorsets; concealed options available
Maintenance
Annual check of seals, hinges and closing action; keep the leaf and frame unobstructed
Compliance
Approved Document B and the project fire strategy govern where a rating is required

Project gallery

Rated doorsets in premium interiors

Hallway doorset, lakeside self build

Hallway doorset, lakeside self build

A rated pair between hall and living space, detailed so the closing sequence is invisible from the hallway.

Location
Windermere
Completed
2025
Products
Steel-look double doors, three-over-three bars
Fire rating
FD30S
Utility to integral garage

Utility to integral garage

The most common domestic requirement, resolved without a flush white slab interrupting a black steel interior.

Location
Kendal
Completed
2025
Products
Single steel-look door, clear certified glazing
Fire rating
FD30S
Protected stairway screen

Protected stairway screen

A full-height screen enclosing the stair while daylight continues to reach the hall.

Location
Penrith
Completed
2025
Products
Doorset with side and over panels, reeded glazing
Fire rating
FD30
Hotel lobby to stair core

Hotel lobby to stair core

Sixty-minute compartmentation presented as a piece of interior architecture rather than a fire door.

Location
South Lakes
Completed
2025
Products
Double doorset and matching partition, bronze hardware
Fire rating
FD60S

Keep the fire rated specification with your other ideas

Save it now and every rating, glass option, finish and handle you like stays grouped with the rest of your project.

Keep exploring

Explore The Rest Of The Internal Steel Collection

Fire rated doorsets are specified from within the same collection, so every product below shares the same profile, finishes and detailing.

Currently viewing: Fire Rated Steel Doors

Internal Steel Single Doors

Internal Steel Single Doors

Beautiful architectural internal steel doors for studies, utility rooms, pantries, bathrooms and room dividers.

View Product
Internal Steel Double Doors

Internal Steel Double Doors

Elegant paired doors creating flexible open-plan living while maintaining separation when required.

View Product
Internal Steel Sliding Doors

Internal Steel Sliding Doors

Slim steel sliding systems allowing spaces to connect without sacrificing natural light.

View Product
Internal Steel Pivot Doors

Internal Steel Pivot Doors

Large-format statement doors with concealed pivot hardware for contemporary interiors.

View Product
Internal Steel Bifold Doors

Internal Steel Bifold Doors

Multi-panel steel glazing allowing complete flexibility between connected spaces.

View Product

Common questions

Fire rated steel doors: your questions answered

The questions homeowners, architects and builders ask us most about certified internal steel doorsets.

Ask Us DirectlyVisit the Knowledge Centre

Start the conversation

If you are planning an extension, renovation or new-build project and want glazing designed and installed without compromise, we would be glad to talk.

Approximate sizes are fine at this stage. Most homeowners simply send drawings or photos of their openings.

Direct

01768 254554projects@windowsinthelakes.co.uk

Send the door schedule or the fire strategy extract and we will tell you which openings we can certify, and what each one needs.

Technical support for architects and builders

Begin

Beautiful steel doors that meet the fire strategy.

Send us the drawings or the door schedule and we will confirm which openings can be certified, in what configuration, and what it should cost.